CV 1500

TECHNICAL SPECIFICATIONS
Inlet Connections welding neck
GAS / NPT threaded
special flange
Outlet Connections GAS male threaded
Nominal diameter 3/4″ – 1″ – 1½”
Minimum passage area 1.65 – 3.14 – 5.15 cm² / 0.255 – 0.486 – 0.798 in
Maximum pressure 400 bar / 5801 psig
Temperature -20 °C +150 °C / -4 °F +302 °F
Body material* Carbon steel ( green zinc plated)
Gasket* FPM rubber, Rubber

 

Approvals

Changeover Valves CV-1500 Series

The changeover valve CV-1500 Series permits to intercept one of two valves mounted on it making operate simultaneously the other one and permitting to carrying out the disassembling and the maintenance of the intercepted valve. The simultaneous interception of the two valves is never possible.

The changeover valve’s use on plants permits to execute the ordinary maintenance of the safety valves without stopping the production and without discharging pressure of equipments, saving time and refilling costs. On changeover valve body threaded connections are available in order to stirrup the changeover valve-safety valve unit. The mounted valves can be positioned in the most opportune direction.

The operation of changeover valve is made by a hand wheel: turning clockwise the hand wheel, the farer valve to the hand wheel itself is intercepted; turning counter clockwise the hand wheel , the closest valve is intercepted. A label positioned on the hand wheel shows the correct rotation to be followed in order intercept the valve that should be removed.

TECHNICAL BROCHURE

USE AND MAINTENANCE MANUAL